86exporter.com Home       Products Catalog      Suppliers Catalog      Log In        Sign up
      About Us
      Profile
      Products
      Contact Us


RONSEDA ELECTRONICS CO.,LTD

Products >> ETCO2+SPO2 Patient Monitor 3.5 Inch RSD2001A

ETCO2+SPO2 Patient Monitor 3.5 Inch RSD2001A

Build Your Online Product Catalogs?



Description
Product Name: ETCO2+SPO2 Patient Monitor 3.5 Inch RSD2001A
Supply Ability:
Related proudcts spo2, patient monitor,
Specifications RSD2001A
Price Term:
Port of loading:
Minimum Order
Unit Price:

***ails£º
RSD2001A is a Portable Patient Monitor that has abundant monitoring functions and is used for the clinical monitoring of adult, pediatric and neonate. In addition, the user may select the different parameter configuration according to different requirements.

RSD2001A (standard)can monitor vital signals correlating to SpO2 and CO2. It integrates parameter measuring modules and display in one device, featuring in co***ctness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. The LCD of high resolution and bright LED display provides clear view of 2 waveforms,SPO2,PR,EtCO2,InCO2,Respiration rate.

Specifications
Display
Messages:
2 Waveforms
2 indicator lights
2 Sound Mode corresponding Alarm Mode
Device:
1 dot matrix LCD size: 3.5", resolution: 256X120
5 digital LED windows

CO2
Method Infra-red Absorption Technique
Measuring mode Sidestream
Side-stream mode sampling gas flow rate
100, 150, 200 ml/Min (option)
Measuring range
CO2 0~99 mmHg
INSCO2 0-99 mmHg
AwRR 0~150 rpm
Resolution
CO2 1 mmHg
INSCO2 1mmHg
AwRR 1 rpm
Accuracy
CO2
2 mmHg,0 ~ 40 mmHg
5% of reading,41 ~ 76 mmHg
10% of reading, 77 ~ 99 mmHg
AwRR 2 rpm
Actualization interval about 1 Sec.
Start-up Time: < 10 sec
Rise Time: 240 msec (10% to 90 %)
Delay Time: 1.12 seconds maximum with 7| length, 0.055|| ID.
Sampling line at 175 ml/min
Alarm range
CO2 0 ~ 99 mmHg
InsCO2 0 ~ 99 mmHg
AwRR 0 ~ 150 rpm
Suffocation Alarm Delay
AwRR 10 ~ 40 Sec

SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization interval about 1Sec
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range
0~254bpm
Resolution 1bpm
Accuracy 2bpm
Alarm Delay 10 Sec.

Recall
Trend Recall
8 to 96hours

Contact Us
Company: RONSEDA ELECTRONICS CO.,LTD
Contact: Ms. Sophi Zhu
Address: 5Fl,51Building,Yangmen Industrial Park,Dakan 2 Village,Xili Town, Nanshan District, Shenzhen,Guangdong, China
Postcode: 518055
Tel: 86-755-86330963
Fax: 86-755-86330961
E-mail:         


Copyright© RONSEDA ELECTRONICS CO.,LTD All Rights Reserved.
Tel : 86-755-86330963 Fax : 86-755-86330961
Powered by 86exporter.com